The vacuum suction cup grinder is the core equipment for precision grinding of quartz ceramic substrates (used for semiconductor packaging and photovoltaic modules), responsible for processing the substrate to a specified thickness (tolerance ± 0.01mm) and ensuring flatness (≤ 0.005mm/m), directly affecting the quality of subsequent coating and cutting processes of the substrate. If there is a large deviation in flatness (exceeding 0.01mm/m) or edge breakage (with a width exceeding 0.2mm), it will result in a substrate scrap rate of over 15% and significantly increase production costs. Based on the characteristics of quartz ceramics with a Mohs hardness of 7-8 and high brittleness, a three-step troubleshooting method is summarized to quickly restore the precision grinding performance.

Step 1: Optimize the vacuum suction cup adsorption and fixture accuracy - Basic guarantee for controlling flatness

The uneven suction of suction cups and insufficient precision of the tabletop are the core reasons for flatness deviation.

Imbalance or leakage of suction cup suction force: The suction cup partition suction pressure deviation exceeds 0.02MPa, and the local stress on the substrate is uneven, resulting in deformation during grinding; Scratches and pores on the suction cup surface cause air leakage, resulting in a decrease in adsorption force (below 0.06MPa) and easy displacement of the substrate. Select porous ceramic vacuum suction cups and divide them into 3-4 adsorption zones according to the substrate size. Adjust the pressure deviation of each zone to ≤ 0.01MPa through a pressure regulating valve; Repair the scratches on the surface of the suction cup with grinding paste, seal the pores, ensure that the adsorption force is stable at 0.08-0.1MPa, and the substrate is not loose after adsorption.

Precision degradation or positioning deviation of suction cup tabletop: The wear of the tabletop flatness exceeds 0.003mm/m, directly causing the substrate grinding reference to deviate; Positioning pin wear exceeds 0.01mm, substrate clamping position deviation, and uneven edge grinding. Calibrate the suction cup table with a laser interferometer, and grind and repair it when it exceeds the tolerance, ensuring that the flatness is ≤ 0.002mm/m; Replace the high-precision positioning pin, use a dial gauge to detect the edge positioning deviation of the substrate after clamping, and control it within ± 0.005mm.

Step 2: Calibrate grinding parameters and wheel configuration - core control to reduce edge collapse

Improper grinding wheel characteristics, grinding speed, and feed rate can exacerbate edge chipping and flatness issues.

Poor adaptability or wear of grinding wheels: ordinary corundum grinding wheels are used, which have insufficient hardness and are prone to abrasive particle detachment. The grinding force fluctuates greatly, and the edges of the substrate are prone to cracking; The grinding wheel has coarse grain size (<800 mesh), deep grinding marks, and large flatness deviation; The end face runout of the grinding wheel exceeds 0.002mm, causing vibration during grinding. Replace the diamond resin bonded grinding wheel (particle size 1000-1200 mesh, medium soft hardness) to adapt to the brittle and hard characteristics of quartz ceramics; Calibrate the grinding wheel with a dynamic balancer, and control the end face runout within ± 0.001mm. Sharpen the grinding wheel for every 50 substrates ground.

Imbalance of grinding parameters: When the linear velocity of the grinding wheel is below 25m/s, the friction between the abrasive particles and the substrate intensifies, and the edges are prone to breakage; Above 40m/s, vibration is enhanced and flatness deviation is large; If the feed rate exceeds 0.005mm/revolution and the grinding load is too high, the substrate is prone to stress cracking. By adjusting the parameters through a frequency converter, the linear speed of the grinding wheel is stabilized at 30-35m/s, and the feed rate is controlled at 0.002-0.003mm/revolution; Adopting the "segmented grinding" mode, coarse grinding (feed rate of 0.004mm/rev) removes most of the excess, fine grinding (feed rate of 0.002mm/rev) ensures accuracy, and the edge area is individually fine tuned to a feed rate of 0.001mm/rev.

Step 3: Adapt substrate characteristics and cooling protection - avoid defects at the source

Insufficient cooling and lubrication, substrate pretreatment, and environmental vibration can affect grinding stability.

Insufficient cooling and lubrication or poor medium adaptation: The coolant flow rate is below 30L/min, which cannot timely remove the grinding heat and cause local thermal stress cracking of the substrate; Insufficient lubricity of the coolant leads to adhesion of abrasive particles, resulting in a sudden increase in grinding force. Select quartz ceramic specific grinding fluid (containing extreme pressure additives, viscosity 5-8mm ²/s), ensure a stable flow rate of 40-50L/min, and install directional nozzles to accurately cover the grinding area and substrate edge with the coolant; Regularly filter the coolant (filtration accuracy ≤ 5 μ m) to avoid impurities scratching the substrate.

Edge defects or environmental interference on the substrate: there are burrs and microcracks on the edge of the substrate blank, which are prone to expand into edge collapse during grinding; The workshop floor vibration exceeds 0.005mm, affecting the accuracy of the grinder operation. Before grinding, use a diamond chamfering tool to chamfer the edge of the substrate blank at 0.2 × 45 ° to remove burrs and microcracks; Install shock-absorbing pads at the bottom of the grinder, away from vibration sources such as stamping and cutting, to ensure that the environmental vibration during grinding is ≤ 0.003mm.

Daily maintenance should pay attention to: checking the suction force of the suction cup, the condition of the grinding wheel, and the flow rate of the coolant every day; Calibrate grinding parameters, wheel dynamic balance, and suction cup flatness weekly; Clean the cooling system monthly and replace aging seals; Quarterly inspection of grinding machine guide rail accuracy and lubrication maintenance. By implementing the above measures, the flatness of the substrate can be reduced to ≤ 0.004mm/m, the edge breakage rate can be lowered to below 3%, and the finished product qualification rate can be significantly improved. If there are still problems, it is recommended to contact the manufacturer to optimize the grinding wheel formula and suction cup adsorption scheme to match the precision grinding needs of quartz ceramic substrates.