Many customers have conducted magnetic separation tests before selection, and
tested the samples in the laboratory. The iron removal effect is very ideal, and
the iron content can be reduced to below the expected value. The equipment can
be pulled to the site and installed, but with the same materials and parameters,
the iron content of the finished product always differs. The problem often lies
not in the equipment itself, but in several easily overlooked variables between
laboratory conditions and production line conditions.
Laboratory samples are usually dried, and the moisture content of production
line materials often exceeds the standard. Dry magnetic separation is extremely
sensitive to material moisture. When conducting experiments in the laboratory,
samples are usually dried to below 1%, and the magnetic separation effect is
naturally good. But the materials on the production line often do not have
sufficient cooling and dehumidification after coming out of the dryer, and the
moisture content may fluctuate between 1.5% -2%. The extra moisture of a few
tenths of a point is enough to cause the fine powder to agglomerate and adhere
on the surface of the magnetic roller, shielding the magnetic field lines and
reducing the iron removal efficiency from over 90% in the laboratory to below
60%. It is recommended to install an online moisture detector in front of the
magnetic separator to ensure that the moisture content of the feed truly meets
the standard, rather than relying on hand feel to judge that it looks dry.
Laboratory experiments use static or small batch feeding, while production
lines use continuous dynamic feeding. In the laboratory, a thin layer of
material is laid on the magnetic roller, and each sand particle has a chance to
get close to the magnetic pole. When the feeding amount on the production line
is increased, the thickness of the material layer changes from a few millimeters
to more than ten millimeters or even thicker. The magnetic particles at the
bottom layer are too far away from the surface of the magnetic roller, and the
magnetic field force rapidly decays. The laboratory data reflects the sorting
effect under ideal fabric conditions, and any slight unevenness or fluctuation
in the thickness of the material layer on the production line may compromise the
effect. It is recommended to install a vibrating feeder in front of the magnetic
separator to stabilize the thickness of the material layer at 5-8mm, and
regularly check whether the feeder is worn and causing material deviation.
Laboratory experiments are often conducted only once, while the properties of
materials on the production line are constantly changing. Different mining
depths, fluctuations in front-end grinding fineness, and even differences in the
degree of weathering of ore surfaces during rainy and dry seasons can all lead
to changes in the occurrence of magnetic impurities in materials. The samples
used in the laboratory experiment may have happened to be batches with lower
iron content and stronger magnetism, and the material properties have already
changed when the production line runs continuously. It is recommended to take
samples and send them for inspection once every quarter, and adjust the
parameters of the magnetic separator in a timely manner according to the actual
material properties, rather than using one set of parameters to the end.
Laboratory data is a reference for selection, not a guarantee of production
line performance. When selecting equipment, sufficient margin should be left,
and after production, fine adjustments should be made according to the actual
material status to truly unleash the design capabilities of the magnetic
separator. Encountering problems during equipment operation, welcome to contact
the technical team of Shandong Heavy Industry for communication: Manager Zhang
13583776655 (same as WeChat).