During the installation and debugging of the equipment, a Gaussian meter was
used to measure the magnetic field strength on the surface of the magnetic
roller, which was 12000Gs. The data fully met the standard, and the manufacturer
accepted it as qualified. The customer was also reassured. After a period of
production, the iron content of the finished product remains so low that no
matter how it is adjusted, it cannot be reduced below the target value. At this
point, many people began to suspect that the magnetic material had demagnetized,
but the retested magnetic field strength still met the standard. Where exactly
is the problem?
Gauss measures the surface of the magnetic roller, but the material is
"sensing" the magnetic field through a layer of material. The magnetic force
decays rapidly with distance, and at a distance of 5mm from the surface of the
magnetic roller, the magnetic field strength may only be 30% of the surface,
while at a distance of 10mm, it may be less than 10%. The thickness of the
material layer on the production line is usually 5-10mm, and the bottom material
is far away from the surface of the magnetic roller. The actual felt magnetic
field force is much lower than the surface measurement value. During laboratory
experiments, the material layer is only thin, and each sand particle is attached
to a magnetic roller, resulting in a naturally good effect. When the material
layer on the production line is thick, the weak magnetic particles at the bottom
cannot be absorbed and are directly discharged with the sand. The solution is
not to replace the magnetic material, but to reduce the thickness of the
material layer by installing a vibrating cloth feeder to stabilize the material
layer within 5mm, while appropriately reducing the feeding speed to allow each
sand particle to have a chance to approach the surface of the magnetic
roller.
The surface of the magnetic roller appears clean, but in reality, there is a
layer of "fouling film" that is invisible to the naked eye. Quartz sand
generates a large amount of fine dust during the crushing and grinding process,
which gradually deposits on the surface of the magnetic roller, forming a thin
powder film. The powder film is not thick and may not be felt by hand, but it is
separated between the magnetic roller and the material, which is equivalent to
increasing the thickness of the material layer and further weakening the
magnetic field force. Even more discreetly, some mineral sources contain trace
amounts of oily substances, forming an oil film on the surface of the magnetic
roller. The fine powder is stuck by the oil and accumulates thicker, making it
impossible to remove with a brush during cleaning. It is recommended to wipe the
surface of the magnetic roller with anhydrous ethanol or cleaning agent every
shift, rather than just using a brush for dry sweeping. When oil gloss or sticky
texture is found on the surface of the magnetic roller, it indicates that an oil
film has formed and needs to be thoroughly cleaned.
The ratio of the magnetic roller speed to the feeding speed determines the
actual residence time of the material in the magnetic field zone. Many operators
only focus on whether the magnetic roller speed is normal, but ignore whether
the feeding speed matches. When the speed of the magnetic roller remains
constant and the feeding speed increases, the residence time of the material on
the magnetic roller is shortened, and the magnetic particles slide over before
they can be adsorbed. When the feeding speed remains constant and the magnetic
roller speed increases, the material distribution on the magnetic roller becomes
thinner. However, as the speed increases, it also affects the adsorption effect.
The correct approach is to adjust the magnetic roller speed and feeding speed as
a whole, and maintain the material's residence time in the magnetic field zone
not less than 1.5 seconds. When making actual adjustments, first fix the feeding
speed and gradually adjust the magnetic roller speed. After each adjustment,
take a sample to test the iron content and find the best matching point.
Meeting the standard for magnetic field strength is only a necessary
condition, not a sufficient condition. The actual magnetic field force felt by
the material is the key to determining the effectiveness of iron removal.
Encountering problems during equipment operation, welcome to contact the
technical team of Shandong Heavy Industry for communication: Manager Zhang
13583776655 (same as WeChat).